3600h Digital output states

This object shall indicate the actual state of the digital outputs. It is a bit-masked value where the bit offset corresponds to the digital output id starting with bit offset 0 = DOUT1.

For example, 3600h value of 0x0000108 means DOUT9.STATE and DOUT4.STATE = 1.

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Digital output states 3600h 0 Unsigned32 - - Read only Yes All